超低溫LNG質量流量計
簡要描述:RETZ進口超低溫LNG質量流量計是測量液化天然氣等低溫介質而研制的。流量計由質量流量傳感器和變送器組成。傳感器具有測量精度高、量程比寬、可靠性高等優點
品牌:RETZ
工況條件:流體測控
溫度/壓力:P-T: 40bar@-200℃
更新時間:2023/04/01
進口超低溫LNG質量流量計 產品用途 Product use
采用高效的隔熱技術有效控制LNG等低溫介質在流經傳感器時與外界的熱交換,降低LNG等低溫介質在管路中的氣化,從而降低氣化對流量計量造成的影響。
Efficient heat insulation technology is used to effectively control the heat exchange between low-temperature media such as LNG and the outside world when flowing through the sensor, reducing the gasification of low-temperature media such as LNG in the pipeline, thereby reducing the impact of gasification on flow measurement
技術參數 Technical parameter
流量測量精度 | 0.1%、0.15%、0.2%、0.5% | 被測介質溫度 | -200℃-100℃ |
重復性 | 0.05%-0.1% | 適用環境溫度 | -30~70℃ |
密度測量范圍 | 0<p<5g/cm3 | 測量管材質 | 316L |
密度測量精度 | ±0.002g/cm3 | 工作壓力 | 常規4MPa,高壓可特殊訂制 |
溫度測量范圍 | -200-350℃ | 防爆型等級 | Exd[ib]IICT1~T6Gb |
溫度測量精度 | ±1℃ | 防護等級 | IP67 |
輸出信號 | 4-20mA直流電流信號、0-10KHZ頻率脈沖信號、脈沖當量信號、RS485通訊信號 |
參考量程表 Reference Range Table
型號 |
公 稱 通 徑 | 推薦流量范圍(kg/h) | 最大流量范圍(kg/h) |
RN-MLG6 | 06 | 0-600 | 0-960 |
RN-MLG15 | 15 | 0-3600 | 0-4500 |
RN-MLG25 | 25 | 0-9600 | 0-12000 |
RN-MLG40 | 40 | 0-30000 | 0-36000 |
RN-MLG50 | 50 | 0-48000 | 0-60000 |
RN-MLG80 | 80 | 0-150000 | 0-180000 |
RN-MLG100 | 100 | 0-240000 | 0-280000 |
科里奧利(科氏力)質量流量計原理 Coriolis mass flowmeter principle
科里奧利質量流量計(Coriolis Mass Flowmeter)簡稱科氏力質量流量計,一個彎管道的兩端被固定,在兩個固定點的中間位置給管道施加振動力(按管道的諧振頻率),使其以固定點為軸以其自然頻率u振動,當管道內沒有流體流動時,管道只受外加震動力作用,管道兩個半段振動方向相同,沒有相位差。當有流體流動時受管道內流動的介質質點科氏力Fc的影響,管道的兩個半段按相反的方向發生扭動,產生相位差,這一相位差同質量流量成正比,這就是科氏質量流量計的工作原理.
Coriolis Mass Flowmeter is referred to as Coriolis force mass flowmeter. Both ends of a curved pipe are fixed, and vibration force (based on the resonance frequency of the pipe) is applied to the pipe at the middle of the two fixed points, making it vibrate at its natural frequency u with the fixed point as the axis. When there is no fluid flow in the pipe, the pipe is only subjected to external vibration force, and the vibration directions of the two halves of the pipe are the same, without phase difference. When there is fluid flowing, influenced by the Coriolis force Fc of the medium particles flowing in the pipe, the two halves of the pipe twist in opposite directions, resulting in a phase difference that is proportional to the mass flow rate. This is the working principle of a Coriolis mass flowmeter
安裝外形尺寸 Installation overall dimensions
三角形分體式
規 格 | A(法蘭間距)mm | B(整體高度)mm | C(外殼厚度)mm |
6 | 161 | 319 | 235 |
15 | 188 | 339 | 293 |
25 | 210 | 539 | 448 |
40 | 262 | 636 | 576 |
U型分體式
規格 | A(法蘭間距)mm | B(整體高度)mm | C(外殼厚度)mm |
50 | 552 | 711 | 506 |
80 | 731 | 893 | 653 |
100 | 755 | 1162 | 709 |